SLS-115/230
Smart Laser Sensor
MONARCH INSTRUMENT
Instruction Manual
15 Columbia Drive
Amherst, NH 03031-2334 USA
Phone: (603) 883-3390
Fax: (603) 886-3300
Website: www.monarchinstrument.com
Printed in the U.S.A.
Copyrighted by Monarch Instrument 2004, all rights reserved
1071-4859-111
CE DECLARATION OF CONFORMITY
As Manufacturer:
Monarch Instrument
Division of Monarch International Inc.
15 Columbia Drive, Amherst NH 03031 USA
declares under Monarch’s sole responsibility that the product:
to which this declaration relates is in conformity with the following directives and
standards when installed and operated in accordance with the user manual:
References: Retlif Testing Laboratories, (Report No. R-4283)
Technical Construction File SLS-0604 of June 2004
SLS - Smart Laser Sensor
15
th
June 2004
Manufacturer (Amherst,NH) Alan Woolfson, VP Engineering (Authorized Signature)
Directives: EMC 89/336/EEC
Low Voltage 73/23/EEC
Standards: EMC: EN61326:1997
Electrical Safety: IEC61010-1:2001
Laser Safety: IEC60825-1:2001
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Smart Laser Sensor

SLS-115/230Smart Laser SensorMONARCH INSTRUMENT Instruction Manual15 Columbia DriveAmherst, NH 03031-2334 USAPhone: (603) 883-3390Fax: (603) 886

Page 2 - 11.0 ACCESSORIES

SAFEGUARDS AND PRECAUTIONSWARNING - This product emits a visible beam of laserlight. Avoid exposure to the laser radiation. The use ofoptical viewin

Page 3 - 9.0 RS232

TABLE OF CONTENTSTABLE OF CONTENTSSymbols on the unit and in this manual:Warning Direct currentLaser BeamCaution Alternating currentRead Manual1.0 SMA

Page 4

11.0 SMART LASER SENSOR SPECIFICATIONSLaser Specifications:Classification: Class 3R (per IEC 60825-1 Ed 1.2 2001-8)Complies with FDA performance stand

Page 5 - 6.0 OPERATION

2Max RPM: 500,000 RPMMin. Trigger Duration: 10 µsecIndicators: LEDs for On Target, Laser On, Auto/Gain, Power/ChargeModes: Normal (manual) or Auto, an

Page 6

3Pulse Output (continued):Polarity: Positive or Negative pulse (switch selectable)RS232: Transmit Out – ASCII value of RPM (Accuracy ±0.002% of readi

Page 7 - 2.0 OVERVIEW

4Weight: 10.6 oz (300.5 grams) excluding cable and chargerCompliance: CE 93/68/EEC EMC directive (EN 61326:2001)IEC 61010-1 2001, IEC 60825-1 2001, C

Page 8 - 4.0 QUICK START GUIDE

53.0 INDICATORS AND SWITCHES1. On Target LED Lit whenever the sensor is receiving areflected signal back from the target. As thefrequency increases,